2010 Gillig LOW FLOOR: complaints, problems and recalls
Explore the records behind recurring owner reports.
Key facts
0 owner complaints analyzed
9 distinct recall campaigns
Not available median reported failure mileage
Scope: 2010 model year. Data snapshot: . 0 complaints include usable failure mileage.
Most common problems
No owner complaints are recorded for this selection. A complaint can name multiple components.
Component breakdown
Number of unique complaints naming each component. Top eight shown.
No usable records for this chart.
| Category | Count |
|---|
No records.
Reported problems by failure mileage
Complaint counts in mileage bands. These are not failure rates per vehicle or mile.
| Category | Count |
|---|---|
| Under 25,000 | 0 |
| 25,000 to 49,999 | 0 |
| 50,000 to 74,999 | 0 |
| 75,000 to 99,999 | 0 |
| 100,000 to 149,999 | 0 |
| 150,000 and above | 0 |
Under 25,000: 0; 25,000 to 49,999: 0; 50,000 to 74,999: 0; 75,000 to 99,999: 0; 100,000 to 149,999: 0; 150,000 and above: 0
No usable failure mileage is recorded. 0 complaints have missing, zero or invalid mileage.
Complaints over time
Year the complaint was filed, not the vehicle model year or incident year. The snapshot year is partial.
No usable records for this chart.
| Category | Count |
|---|
No records.
Pattern summary
There is not enough complaint evidence to summarize patterns.
Calculated from recorded counts. An AI narrative has not been published for this selection.
Examples from the source records
Examples provide context, not a representative sample or a verified diagnosis.
Recall history
9 distinct campaigns affect this selection. Announcement dates below are different from vehicle model years. A campaign may cover multiple years.
11V411000 · Engine And Engine Cooling
Reported: 2011-08-10 (August 10, 2011)
GILLIG IS RECALLING CERTAIN MODEL YEAR 2010-2011 LOWFLOOR BUSES EQUIPPED WITH CUMMINS ENGINES. THE V-BAND CLAMP ASSEMBLY USED TO CONNECT THE INLET AND OUTLET CONE SECTIONS TO THE DIESEL OXIDATION CATALYST (DOC) DIESEL PARTICULATE FILTER (DPF) INCLUDE A T-BOLT WHICH CAN FRACTURE AND FAIL WHEN SUBJECTED TO STRESS OR LOAD. A FRACTURE OR FAILURE OF THE T-BOLT MAY CAUSE THE CLAMP TO LOOSEN AND THE INLET OR OUTLET SECTIONS ATTACHED TO THE DOC/DPF HOUSING TO DISCONNECT.
Consequence: IF THE INLET OR OUTLET SECTIONS DISCONNECT, HOT EXHAUST GASES CAN VENT PRIOR TO EXITING THE TAILPIPE, CREATING THE RISK OF COMBUSTION AND A FIRE. IF BOTH CLAMPS FAIL, THERE IS A RISK IN SOME APPLICATIONS THAT THE DOC/DPF HOUSING MAY DETACH COMPLETELY, CREATING A ROAD HAZARD.
Remedy: GILLIG IS WORKING WITH CUMMINS TO IDENTIFY OWNERS. CUMMINS IS HANDLING THE OWNER NOTIFICATION AND REMEDY FOR THIS CAMPAIGN PLEASE SEE NHTSA RECALL 11E-031. OWNERS MAY CONTACT CUMMINS AT 1-812-377-5000.
NHTSA campaign record ↗12V506000 · Visibility:Glass, Side/Rear
Reported: 2012-10-18 (October 18, 2012)
Gillig is recalling certain model year 2010 Lowfloor transit buses, manufactured April 16, 2010, through November 16, 2010, and equipped with Ricon 3-Minute Urban Transit Bus Window sets. The composition of the material used to cast the handle that opens the egress window is incorrect, resulting in a reduction in material strength. The handle(s) on the emergency egress passenger windows may break before the window latch is released.
Consequence: In the event the egress window handle fails during an actual emergency situation, passengers may be trapped in the vehicle placing them at risk of injury.
Remedy: Gillig will notify owners, and dealers will replace the window handles free of charge. The recall began during October 2012. Owners may contact Gillig at 1-800-735-1500 for more information.
NHTSA campaign record ↗14V084000 · Engine And Engine Cooling:Engine
Reported: 2014-02-27 (February 27, 2014)
Gillig LLC is recalling certain model year 2010-2014 Lowfloor transit buses manufactured August 26, 2010, through February 14, 2014, and equipped with certain Cummins Westport model ISL G engines. Condensation in the intake manifold may freeze during cold weather conditions and interfere with the proper operation of the intake manifold pressure sensor.
Consequence: The improper operation of the sensor could induce elevated exhaust temperatures or flames from the exhaust pipe, increasing the risk of a vehicle fire.
Remedy: Cummins Inc. and Cummins Wesport Inc. will notify owners, and dealers will upload a new ECM calibration, free of charge. The recall began on March 20, 2014. Owners may contact Gillig LLC at 1-510-785-1500 or Cummins Inc. at 1-800-343-7357.
NHTSA campaign record ↗14V358000 · Engine And Engine Cooling:Engine
Reported: 2014-06-23 (June 23, 2014)
Gillig, LLC (Gillig) is recalling certain model year 2007-2014 Lowfloor transit buses manufactured September 26, 2007, through January 24, 2014. In the affected vehicles, the engine oil sampling hose may leak oil due to being routed too closely to hot engine exhaust components.
Consequence: If the sampling hose leaks oil in the presence of hot engine engine exhaust components, there is an increased risk of fire.
Remedy: Gillig will notify owners, and dealers will inspect the oil sampling hose. If the hose is routed too closely, the hose will be removed, replaced and rerouted to provide appropriate clearance of the hot components. The recall is expected to begin in early August 2014. Owners may contact Gillig customer service at 1-800-735-1500.
NHTSA campaign record ↗15V262000 · Engine And Engine Cooling:Engine
Reported: 2015-05-05 (May 5, 2015)
Gillig LLC (Gillig) is recalling certain model year 2010-2015 Lowfloor vehicles manufactured August 26, 2010, to April 30, 2015. Excessive engine crankcase pressures may cause the 90-degree elbow of the vent tube assembly to detach from the crankcase ventilation breather, possibly allowing engine oil to come into contact with hot surfaces.
Consequence: If engine oil comes into contact with a hot surface, there is an increased risk of a fire.
Remedy: Gillig will notify owners, and dealers will secure the ends of the 90-degree elbow. In addition, the electronic control module (ECM) will be reprogrammed with software that can adjust the engine output under misfire conditions to limit crankcase pressures. These repairs will be performed free of charge. The recall began on June 2, 2015. Owners may contact Gillig customer service at 1-800-735-1500.
NHTSA campaign record ↗15V420000 · Electrical System:Wiring:Front Underhood
Reported: 2015-07-01 (July 1, 2015)
Gillig LLC (Gillig) is recalling certain model year 2010-2015 Low Floor transit buses manufactured April 13, 2010, to June 12, 2015. Due to the routing of the grid heater electrical power cable, the cable may chafe against a fuel injector hard line.
Consequence: If the electrical power cable rubs against the injector fuel line, the cable may short circuit or the fuel line may leak fuel. Either possibility increases the risk of a fire.
Remedy: Gillig will notify owners, and dealers will inspect the grid heater power cable/hard injector fuel line for wear, and will properly route and support the grid heater power cable, free of charge. The recall began on July 17, 2015. Owners may contact Gillig customer service at 1-800-735-1500.
NHTSA campaign record ↗16V011000 · Seats
Reported: 2016-01-13 (January 13, 2016)
Gillig LLC (Gillig) is recalling certain model year 2010-2015 Low Floor transit buses manufactured April 1, 2010 to October 30, 2015, equipped with Recaro Ergo-M Commercial Bus Driver Seats. The affected seats have J-Brackets that may be missing welds which could allow the seat belt anchorage assembly to separate from the J-Bracket.
Consequence: If the seatbelt anchorage assembly separates from the J-Bracket, the bus driver may not be properly restrained in the event of a crash increasing their risk of injury.
Remedy: Gillig will notify the owners, and dealers will inspect the seats to determine if welds are missing. Any J-Bracket that is missing welds will be removed and replaced, free of charge. The recall began on March 1, 2016. Owners may contact Gillig customer service at 1-800-735-1500.
NHTSA campaign record ↗17V119000 · Exterior Lighting:Turn Signal
Reported: 2017-02-24 (February 24, 2017)
Gillig LLC (Gillig) is recalling certain model year 1997-2017 Low Floor transit buses. The front turn signals installed on standard profile (non-BRT) buses may not be sufficiently visible to other drivers or pedestrians. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard number 108, "Lamps, Reflective Devices, and Associated Equipment."
Consequence: The reduced visibility of the turn signals may increase the risk of a crash.
Remedy: Gillig will notify owners, and dealers will install turn signals that have increased visibility. The recall began June 7, 2019. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.
NHTSA campaign record ↗18V418000 · Exterior Lighting:Turn Signal:Flasher Unit | Exterior Lighting:Turn Signal
Reported: 2018-06-20 (June 20, 2018)
Gillig LLC (Gillig) is recalling certain 2001-2018 Gillig Low Floor transit buses. The turn signals may flash slowly, reducing their visibility to other drivers. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard (FMVSS) number 108, "Lamps, Reflective Devices, and Associated Equipment."
Consequence: The reduced visibility of the turn signals can increase the risk of a crash.
Remedy: Gillig will notify owners, and dealers will update the software that controls the turn flash rate, free of charge. The recall began on August 2, 2018. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.
NHTSA campaign record ↗