Horton TYPE I recalls by model year
Explore the records behind recurring owner reports.
Key facts
1 owner complaints analyzed
8 distinct recall campaigns
6,000 mi median reported failure mileage
Scope: 2016 to 2026 model years. Data snapshot: . 1 complaints include usable failure mileage.
Recalls by model year
All campaigns in the snapshot affecting each model year, including recalls announced years later.
Recall campaigns
Shared campaigns appear once in each affected model year.
| Category | Count |
|---|---|
| 2016 | 2 |
| 2017 | 3 |
| 2018 | 6 |
| 2019 | 5 |
| 2020 | 3 |
| 2025 | 1 |
| 2026 | 1 |
2016: 2; 2017: 3; 2018: 6; 2019: 5; 2020: 3; 2025: 1; 2026: 1
Year-by-year records
Recall history
8 distinct campaigns affect this selection. Announcement dates below are different from vehicle model years. A campaign may cover multiple years.
19V281000 · Back Over Prevention: Sensing System: Camera
Reported: 2019-04-09 (April 9, 2019) · Model years: 2016, 2017, 2018, 2019
Halcore Group, Inc. (Halcore) is recalling certain 2016-2019 Horton Type I and Type III ambulances equipped with ASA Electronics back-up camera displays. The displays may revert back to the factory default settings which may cause the camera image to be reversed.
Consequence: The driver may inadvertently turn the wrong direction to avoid an object behind the vehicle, increasing the risk of a crash.
Remedy: Horton will notify owners and dealers will add a harness relay capacitor module to prevent the image from reversing, free of charge. The recall began June 13, 2019. Owners may contact ASA customer service at 1-800-384-4400 or Halcore at 1-800-447-0343.
NHTSA campaign record ↗20V128000 · Equipment:Electrical
Reported: 2020-03-04 (March 4, 2020) · Model years: 2016, 2017, 2018, 2019
Halcore Group, Inc. (Halcore) is recalling certain 2016-2019 Horton Emergency Vehicles Type I and Type III ambulances. The A/C input power cord for the Sensata inverter may be undersized for certain inverter applications, possibly resulting in an electrical short circuit.
Consequence: An electrical short circuit increases the risk of a fire or a shock hazard.
Remedy: Halcore has notified owners, instructing them to contact Sensata for a replacement power cord, free of charge. The recall began March 10, 2020. Owners may contact Halcore customer service at 1-800-447-0343.
NHTSA campaign record ↗18V605000 · Exterior Lighting:Brake Lights
Reported: 2018-09-11 (September 11, 2018) · Model years: 2017, 2018
Halcore Group, Inc. (Halcore) is recalling certain 2017-2018 Horton Type I and Type III ambulances, equipped with Whelen accessory brake lights. Depending on the specific wiring of the vehicle, these brake lights may illuminate when the brake pedal has not been pressed. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard (FMVSS) number 108, "Lamps, Reflective Devices, and Associated Equipment."
Consequence: If the brake lights incorrectly illuminate, it can confuse other drivers, possibly increasing the risk of a crash.
Remedy: Halcore will notify owners, and Whelen will replace the brake lights, free of charge. The recall began October 16, 2018. Owners may contact Halcore customer service at 1-800-447-0343.
NHTSA campaign record ↗19V608000 · Air Bags
Reported: 2019-08-19 (August 19, 2019) · Model years: 2018, 2019, 2020
Halcore Group, Inc. (Halcore) is recalling certain 2018-2020 Horton Type I and Type III Emergency vehicles. Due to improper manufacturing, the cushion of the Inflatable Head Cushion (IHC) and Knee Air Bag (KAB) may detach during a deployment event and not inflate.
Consequence: In the event of a crash, if the cushions do not inflate properly, they may not provide the intended protection to the occupant, increasing the risk of injury.
Remedy: Halcore will notify owners and dealers will install replacement air bags when they become available, free of charge. Halcore issued owners an interim notification on September 6, 2019. The recall began September 20, 2019. Owners may contact Halcore customer service at 1-800-447-0343.
NHTSA campaign record ↗19V742000 · Equipment
Reported: 2019-10-17 (October 17, 2019) · Model years: 2018, 2019
Halcore Group, Inc. (Halcore) is recalling certain 2018-2019 Horton Type I & Type III ambulances. The D-cylinder oxygen tank bracket may loosen, allowing the oxygen tank to separate and become airborne in the event of a crash.
Consequence: An unsecured oxygen tank may strike ambulance occupants and increasing the risk of injury in the event of a crash.
Remedy: Halcore will notify owners, and Ziamatic will refund the purchase price paid, or provide replacement bracket assemblies, free of charge. The recall began November 7, 2019. Owners may contact Halcore customer service at 1-800-447-0343.
NHTSA campaign record ↗20V291000 · Service Brakes | Service Brakes, Hydraulic:Foundation Components:Hoses, Lines/Piping, And Fittings | Suspension:Rear
Reported: 2020-05-20 (May 20, 2020) · Model years: 2018, 2019, 2020
Halcore Group, Inc. (Halcore) is recalling certain 2018-2020 Horton Emergency Vehicles (HEV) Type I & Type III ambulances built on a Ram 4500 or 5500 chassis and equipped with Compressible Liquid Adaptive Suspension Systems (C.L.A.S.S.), part numbers DS135RS3A, DS135RS3AF, DS135RS3-DM. The rear brake caliper flexible line may have been routed so that it contacts a suspension component, possibly causing excessive wear and a loss of rear brakes. The affected system component is the rear brake caliper flexible line which may be causing brake caliper to wear due to contact suspension components.
Consequence: A worn rear brake caliper flexible line may cause brake fluid leakage which may result in a partial or complete loss of the rear brakes, increasing the risk of a crash.
Remedy: Halcore will notify owners, and dealers will inspect the rear brake caliper flexible lines for wear and install a kit to modify the rear brake caliper flexible line mounting, and if necessary, a kit to replace worn brake lines, free of charge. This recall began June 5, 2020. Owners may contact Halcore customer service at 1-800-447-0343.
NHTSA campaign record ↗20V745000 · Electrical System
Reported: 2020-12-01 (December 1, 2020) · Model years: 2020
Halcore Group, Inc. (Halcore) is recalling certain 2020 Horton Emergency Vehicles Type I and III and ambulances equipped with Weldon i4G Vivtech Displays. The processor that runs the display may stop functioning without warning, causing items operated through the control panel to not function.
Consequence: If the control panel stops functioning, a delay in emergency services may occur, increasing the risk of injury.
Remedy: Halcore will notify owners, and dealers will inspect and repair the i4G Vivtech rear and/or front display within the serial number range, free of charge. The recall began December 8, 2020. Owners may contact Halcore customer service at 1-800-447-0343.
NHTSA campaign record ↗26V533000 · Equipment:Emergency:Siren/Lighting/Strobes:Controls | Equipment:Electrical:Infotainment:Video (Touch)Screen/Monitor/Unit | Equipment:Emergency:Fire Supression
Reported: 2026-08-14 (August 14, 2026) · Model years: 2025, 2026
Halcore Group, Inc. (Halcore) is recalling certain 2025-2026 Horton Type I, Type III, and Critical Care ambulances. The touchscreen display may stop responding to touch commands or fail to power on, preventing the activation of exterior emergency lights, as well as fire fighting and other emergency equipment.
Consequence: A loss of exterior lights can reduce the visibility of the vehicle to other drivers, increasing the risk of a crash. Inoperative equipment can delay emergency response, increasing the risk of injury.
Remedy: Weldon Division of Akron will update the firmware and repair the power line, free of charge. Owner notification letters are expected to be mailed October 5, 2026. Owners may contact Weldon customer service at 1-800-228-1161 or Halcore customer service at 1-800-447-0343.
NHTSA campaign record ↗