vehicle signal
U.S. public vehicle records

2000 Tiffin ALLEGRO: complaints, problems and recalls

Explore the records behind recurring owner reports.

Key facts

10 owner complaints analyzed

5 distinct recall campaigns

28,000 mi median reported failure mileage

Scope: 2000 model year. Data snapshot: . 3 complaints include usable failure mileage.

Owner-reported patterns

Most common problems

Electrical System is the most frequently named component, appearing in 2 of 10 complaints (20.0%). A complaint can name multiple components.

Recurring terms in complaint narratives
TopicMatching reportsShare of complaints
Braking behavior440.0%
Steering behavior110.0%

Topic matches use published keyword rules. They describe mentions, including negations or comparisons, and do not confirm a diagnosis. Read the matching rules.

Component breakdown

Number of unique complaints naming each component. Top eight shown.

Electrical System
2
Equipment:Recreational Vehicle/Trailer
2
Tires:Sidewall
2
Electrical System:Alternator/Generator/Regulator
1
Electrical System:Wiring
1
Electrical System:Wiring:Fuses And Circuit Breakers
1
Engine
1
Equipment
1
Component breakdown data
CategoryCount
Electrical System2
Equipment:Recreational Vehicle/Trailer2
Tires:Sidewall2
Electrical System:Alternator/Generator/Regulator1
Electrical System:Wiring1
Electrical System:Wiring:Fuses And Circuit Breakers1
Engine1
Equipment1

Electrical System: 2; Equipment:Recreational Vehicle/Trailer: 2; Tires:Sidewall: 2; Electrical System:Alternator/Generator/Regulator: 1; Electrical System:Wiring: 1; Electrical System:Wiring:Fuses And Circuit Breakers: 1; Engine: 1; Equipment: 1

Reported problems by failure mileage

Complaint counts in mileage bands. These are not failure rates per vehicle or mile.

Under 25,000
1
25,000 to 49,999
2
50,000 to 74,999
0
75,000 to 99,999
0
100,000 to 149,999
0
150,000 and above
0
Reported problems by failure mileage data
CategoryCount
Under 25,0001
25,000 to 49,9992
50,000 to 74,9990
75,000 to 99,9990
100,000 to 149,9990
150,000 and above0

Under 25,000: 1; 25,000 to 49,999: 2; 50,000 to 74,999: 0; 75,000 to 99,999: 0; 100,000 to 149,999: 0; 150,000 and above: 0

25,000 to 49,999 miles has the most reports with usable mileage (2). 7 complaints have missing, zero or invalid mileage.

Complaints over time

Year the complaint was filed, not the vehicle model year or incident year. The snapshot year is partial.

2000
1
2001
4
2004
2
2005
1
2006
1
2025
1
Complaints over time data
CategoryCount
20001
20014
20042
20051
20061
20251

2000: 1; 2001: 4; 2004: 2; 2005: 1; 2006: 1; 2025: 1

Pattern summary

Electrical System leads the component reports. Braking behavior appears in 4 complaint narratives. Steering behavior appears in 1 complaint narratives. Use these patterns to inspect individual reports and prepare questions for a mechanic.

Calculated from recorded counts. An AI narrative has not been published for this selection.

Examples from the source records

Examples provide context, not a representative sample or a verified diagnosis.

Owner report 10086201 · 2004-08-04 (August 4, 2004)

WE EXPERIENCED A TIRE BLOW OUT ON OUR 2000 ALLEGRO BUS ON THE BACK RIGHT OUTSIDE TIRE. WE GOT THE TIRE REPAIRED AND DROVE ABOUT 20 MILES AND HAD ANOTHER BLOW OUT ON THE FRONT RIGHT SIDE. MICHELINE DOES NOT ADMIT TO A PROBLEM, BUT THE WEIGHT AND TIRE PRESSURE WERE CORRECT FOR THE TIRES. THE TIRES AND MOTOR HOME HAVE ABOUT 35,000 MILES. *AK

Owner-reported narrative. Look up ODI 10086201 at NHTSA ↗

Owner report 10091791 · 2004-11-03 (November 3, 2004)

WHILE DRIVING 63 MPH RIGHT REAR INNER TIRE EXPERIENCED A BLOWOUT ON A TIFFIN, ALLEGRO BUS 2000 RV WITH TWO ADULTS IN IT. ORIGINAL EQUIPMENTS, TIRE SIZE 255/80R22.5, DOT # B6H6AK3X0100. MANUFACTURER WAS NOT NOTIFIED. *AK THE CONSUMER REPLACED ALL FOUR TIRES. *TC

Owner-reported narrative. 28,000 miles reported. Look up ODI 10091791 at NHTSA ↗

Owner report 10111793 · 2005-02-18 (February 18, 2005)

AFTER PULLING ONTO THE INTERSTATE THE VEHICLE SHUT DOWN. THERE WAS NO STEERING AND NO BRAKES. CONSUMER WAS ABLE TO STOP THE VEHICLE, AND THERE WAS FLUID ON THE GROUND. THE VEHICLE WAS TOWED, AND THE POWER BOOSTER HAD TO BE REPLACED.*AK

Owner-reported narrative. 4,350 miles reported. Look up ODI 10111793 at NHTSA ↗

Owner report 10170210 · 2006-10-07 (October 7, 2006)

2000 CHEVY P-30 CHASSIS AUTO PARK THE "AUTO PARK/EMERGENCY BRAKE" SYSTEM FAILS. THIS CAN HAPPEN GOING DOWN THE ROAD AT WHAT EVER SPEED YOU ARE DRIVING OR SITTING STILL. *NM

Owner-reported narrative. 45,095 miles reported. Look up ODI 10170210 at NHTSA ↗

Owner report 11696412 · 2025-10-29 (October 29, 2025)

Cummins engine serial number 73927429 Isb6.7l Premature failed turbo actuator Known issue being ignored by Cummins.

Owner-reported narrative. Look up ODI 11696412 at NHTSA ↗

Owner report 557165 · 2000-11-08 (November 8, 2000)

WHILE DRIVING IN THE RAIN, VEHICLE'S ENGINE STARTED TO MISS FIRE AND AT TIMES IT COMPLETELY SHUT OFF AND WOULD DROP 5-10 MPH OF SPEED, DEALER FOUND THE AIR FILTER TO BE COMPLETELY SATURATED WITH WATER, THE FILTER HOUSING AND INTAKE TUBE WERE ALSO FILLED WITH LARGE QUANTITIES OF WATER, THE DEALER REPLACED THE AIR FILTER. *SLC

Owner-reported narrative. Look up ODI 557165 at NHTSA ↗

Owner report 558970 · 2001-01-19 (January 19, 2001)

THE TIRES THAT CAME WITH THE VEHICLE (MICHELIN 235/80 XRV ON 22.5 INCH RIMS) WERE PROPERLY INFLATED WHEN THE INNER LEFT REAT TIRE BLEWOUT DUE TO A DEFECT IN THE SIDEWALL, CAUSING DAMAGE TO THE FENDER WELL COVER. NLM

Owner-reported narrative. Look up ODI 558970 at NHTSA ↗

Owner report 879062 · 2001-01-25 (January 25, 2001)

RECEIVED RECALL 00E048000 IN MAIL. CONTACTED MOTOR HOME DEALERSHIP. WAS INFORMED THAT NO PARTS WERE AVAILABLE FOR REPAIRS OF SEAT BELT BUCKLES.*AK

Owner-reported narrative. Look up ODI 879062 at NHTSA ↗

Recall history

5 distinct campaigns affect this selection. Announcement dates below are different from vehicle model years. A campaign may cover multiple years.

01V097008 · Seat Belts:Front:Buckle Assembly

Reported: 2001-06-22 (June 22, 2001)

VEHICLE DESCRIPTION: MOTOR HOMES EQUIPPED WITH SAFETY BELT ASSEMBLIES PRODUCED BY AM-SAFE. ON SOME SEAT BELTS, THE BUCKLE AND CONNECTOR MAY UNLATCH DURING A COLLISION.

Consequence: SERIOUS INJURY OR DEATH COULD OCCUR IF THE VEHICLE OCCUPANT IS NOT PROPERLY RESTRAINED.

Remedy: AM-SAFE NOTIFIED TIFFIN'S CUSTOMERS TO RETURN THEIR VEHICLE TO AN AUTHORIZED DEALER TO HAVE THE SEAT BELTS REPAIRED FREE OF CHARGE. OWNER NOTIFICATION BEGAN AUGUST 31, 2000. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT AM-SAFE COMMERCIAL PRODUCTS AT 219-266-8330.

NHTSA campaign record ↗
03V149000 · Service Brakes, Hydraulic:Brake Fluid Low Warning: Lamp

Reported: 2003-04-14 (April 14, 2003)

CERTAIN MOTOR HOME CHASSIS FAIL TO COMPLY WITH THE REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 105, "HYDRAULIC AND ELECTRIC BRAKE SYSTEMS." THE BRAKE SYSTEM WARNING INDICATOR MAY NOT FUNCTION AS REQUIRED BY STANDARD.

Consequence: IN SOME OF THE AFFECTED VEHICLES, THE BRAKE SYSTEM WARNING INDICATOR WILL NOT ILLUMINATE WHEN THE IGNITION IS IN THE START POSITION OR FOR A LOW BRAKE FLUID CONDITION, IF THE BODY BUILDER RELIED SOLELY UPON FORD'S IVM COMPLIANCE STATEMENT FOR THE BRAKE SYSTEM WARNING INDICATOR.

Remedy: DEALERS WILL REPAIR THE BRAKE WARNING LAMP CIRCUIT. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT TIFFIN AT 1-256-356-8661.

NHTSA campaign record ↗
07V517000 · Equipment:Recreational Vehicle/Trailer

Reported: 2007-11-05 (November 5, 2007)

ON CERTAIN MOTOR HOMES EQUIPPED WITH A TWO-DOOR REFRIGERATOR MANUFACTURED BY THE DOMETIC CORPORATION, THESE REFRIGERATORS MAY HAVE A DEFECT IN THE BOILER TUBE. PRESSURIZED COOLANT SOLUTION COULD BE RELEASED INTO AN AREA WHERE AN IGNITION SOURCE (GAS FLAME) IS PRESENT.

Consequence: RELEASE OF COOLANT UNDER CERTAIN CONDITIONS COULD IGNITE AND RESULT IN A FIRE.

Remedy: TIFFIN MOTORHOMES WILL BE WORKING WITH DOMETIC IN ORDER TO REPAIR THESE REFRIGERATORS (PLEASE SEE 06E076). DOMETIC WILL REPAIR THESE REFRIGERATORS BY INSTALLING A SECONDARY BURN HOUSING, A THERMAL FUSE, AND A MELT FUSE FREE OF CHARGE. DOMETIC HAS RETAINED STERICYCLE INC. TO MANAGE THIS CAMPAIGN. STERICYCLE WILL ASSIST THE OWNER IN LOCATING DEALERSHIPS OR SERVICE CENTERS AND WILL PROVIDE ASSISTANCE WITH SCHEDULING OF APPOINTMENTS. OWNERS MAY CONTACT DOMETIC/STERICYCLE AT 1-888-446-5157 OR TIFFIN AT 1-256-356-8661.

NHTSA campaign record ↗
10V585000 · Equipment:Recreational Vehicle/Trailer

Reported: 2010-11-22 (November 22, 2010)

TIFFIN IS RECALLING CERTAIN RECREATIONAL VEHICLES EQUIPPED WITH 1200-SERIES NORCOLD REFRIGERATORS. THE POPULATION OF REFRIGERATORS BEING ADDRESSED CONTAINS EITHER A SENSING ALGORITHM OR THERMAL SWITCH TO SHUT OFF POWER TO THE REFRIGERATOR WHEN HIGH TEMPERATURES ARE DETECTED IN ORDER TO PREVENT A POTENTIAL FIRE. THE RESPONSE TIMES OF THE SENSOR ALGORITHM AND THERMAL SWITCH DEVICES TO STOP POWER ARE NOT SUFFICIENT.

Consequence: THE SENSING ALGORITHM OR THERMAL SWITCH INSTALLED TO SHUT OFF POWER TO THE REFRIGERATOR WHEN HIGH TEMPERATURES ARE DETECTED DUE TO A POSSIBLE HYDROGEN GAS LEAK MAY NOT SHUT OFF IN SUFFICIENT TIME TO PREVENT A FIRE.

Remedy: TIFFIN IS WORKING WITH NORCOLD TO IDENTIFY AND NOTIFY ANY AFFECTED OWNERS. OWNERS WILL BE INSTRUCTED TO CONTACT NORCOLD DEALERS TO RECEIVE THE REMEDY FREE OF CHARGE. PLEASE SEE NORCOLD'S DEFECT REPORT 10E-049 FOR ADDITIONAL INFORMATION. THE RECALL BEGAN ON FEBRUARY 17, 2011. OWNERS MAY CONTACT NORCOLD AT 1-800-767-9101 OR TIFFIN AT 1-256-356-8661.

NHTSA campaign record ↗
11V082000 · Equipment:Recreational Vehicle/Trailer

Reported: 2011-02-08 (February 8, 2011)

TIFFIN MOTORHOMES IS RECALLING CERTAIN RECREATIONAL VEHICLES EQUIPPED WITH 1200-SERIES NORCOLD REFRIGERATORS. THE POPULATION OF REFRIGERATORS BEING ADDRESSED CONTAINS EITHER A SENSING ALGORITHM OR THERMAL SWITCH TO SHUT OFF POWER TO THE REFRIGERATOR WHEN HIGH TEMPERATURES ARE DETECTED IN ORDER TO PREVENT A POTENTIAL FIRE. THE RESPONSE TIMES OF THE SENSOR ALGORITHM AND THERMAL SWITCH DEVICES TO STOP POWER ARE NOT SUFFICIENT.

Consequence: THE SENSING ALGORITHM OR THERMAL SWITCH INSTALLED TO SHUT OFF POWER TO THE REFRIGERATOR WHEN HIGH TEMPERATURES ARE DETECTED DUE TO A POSSIBLE HYDROGEN GAS LEAK MAY NOT SHUT OFF IN SUFFICIENT TIME TO PREVENT A FIRE.

Remedy: TIFFIN MOTORHOMES IS WORKING WITH NORCOLD TO IDENTIFY AND NOTIFY ANY AFFECTED OWNERS. OWNERS WILL BE INSTRUCTED TO CONTACT NORCOLD DEALERS TO RECEIVE THE REMEDY FREE OF CHARGE. PLEASE SEE NORCOLD'S DEFECT REPORT 10E-049 FOR ADDITIONAL INFORMATION. THE SAFETY RECALL BEGAN ON FEBRUARY 17, 2011. OWNERS MAY CONTACT NORCOLD AT 1-800-767-9101.

NHTSA campaign record ↗