vehicle signal
U.S. public vehicle records

2018 Thomas Built Buses SAF-T-LINER C2: complaints, problems and recalls

Explore the records behind recurring owner reports.

Key facts

1 owner complaints analyzed

22 distinct recall campaigns

2,100 mi median reported failure mileage

Scope: 2018 model year. Data snapshot: . 1 complaints include usable failure mileage.

Owner-reported patterns

Most common problems

Structure:Body is the most frequently named component, appearing in 1 of 1 complaints (100.0%). A complaint can name multiple components.

Component breakdown

Number of unique complaints naming each component. Top eight shown.

Structure:Body
1
Component breakdown data
CategoryCount
Structure:Body1

Structure:Body: 1

Reported problems by failure mileage

Complaint counts in mileage bands. These are not failure rates per vehicle or mile.

Under 25,000
1
25,000 to 49,999
0
50,000 to 74,999
0
75,000 to 99,999
0
100,000 to 149,999
0
150,000 and above
0
Reported problems by failure mileage data
CategoryCount
Under 25,0001
25,000 to 49,9990
50,000 to 74,9990
75,000 to 99,9990
100,000 to 149,9990
150,000 and above0

Under 25,000: 1; 25,000 to 49,999: 0; 50,000 to 74,999: 0; 75,000 to 99,999: 0; 100,000 to 149,999: 0; 150,000 and above: 0

Under 25,000 miles has the most reports with usable mileage (1). 0 complaints have missing, zero or invalid mileage.

Complaints over time

Year the complaint was filed, not the vehicle model year or incident year. The snapshot year is partial.

2018
1
Complaints over time data
CategoryCount
20181

2018: 1

Pattern summary

Structure:Body leads the component reports. Use these patterns to inspect individual reports and prepare questions for a mechanic.

Calculated from recorded counts. An AI narrative has not been published for this selection.

Examples from the source records

Examples provide context, not a representative sample or a verified diagnosis.

Owner report 11084351 · 2018-04-10 (April 10, 2018)

A 2018 THOMAS BUILT TYPE C SCHOOL BUS WAS TRAVELING AT A SPEED OF APPROXIMATELY 42 MPH ON A CITY/URBAN STREET WITH 5 PASSENGERS, PLUS THE OPERATOR ON BOARD. A TREE FELL AND STRUCK THE BUS NEAR, OR ON, THE RIGHT FRONT WINDSHIELD/ROOF AREA. THIS IMPACT CAUSED THE ENTIRE ROOF AREA TO COLLAPSE WITH SEVERE DAMAGE THROUGHOUT THE ENTIRE LENGTH OF THE BUS.

Owner-reported narrative. 2,100 miles reported. Look up ODI 11084351 at NHTSA ↗

Recall history

22 distinct campaigns affect this selection. Announcement dates below are different from vehicle model years. A campaign may cover multiple years.

17V453000 · Equipment

Reported: 2017-07-17 (July 17, 2017)

Daimler Trucks North America LLC (DTNA) is recalling certain 2005-2018 Thomas Built Buses Saf-T-Liner C2 school buses. In the event of a crash, the wheelchair pocket track anchorage may not adequately secure a the wheelchair.

Consequence: In the event of a crash, an unsecured wheelchair may increase the risk of injury.

Remedy: DTNA will notify owners, and dealers will add additional fasteners to the wheelchair pocket track to reinforce the anchorage, free of charge. An interim notice was sent to owners on September 13, 2017. The recall began on December 20, 2017. Owners may contact DTNA customer service at 1-800-745-8000. DTNA's number for this recall is FL-743.

NHTSA campaign record ↗
17V454000 · Equipment

Reported: 2017-07-17 (July 17, 2017)

Daimler Trucks North America LLC (DTNA) is recalling certain 2005-2018 Thomas Built Buses Saf-T-Liner C2 transit buses. In the event of a crash, the wheelchair pocket track anchorage may not adequately secure a the wheelchair.

Consequence: In the event of a crash, an unsecured wheelchair may increase the risk of injury.

Remedy: DTNA will notify owners, and dealers will add additional fasteners to the wheelchair pocket track to reinforce the anchorage, free of charge. An interim letter was mailed on September 13, 2017. The recall began on December 20, 2017. Owners may contact DTNA customer service at 1-800-745-8000. DTNA's number for this recall is FL-743.

NHTSA campaign record ↗
17V587000 · Seats

Reported: 2017-09-21 (September 21, 2017)

Daimler Trucks North America LLC (DTNA) is recalling certain 2014-2018 Thomas Built Buses Saf-T-Liner HDX and Saf-T-Liner C2 school buses. A reinforcement bracket may be missing from the seats that have 3-point seat belts.

Consequence: Without the reinforcement bracket, the seat may not be adequately secured, increasing the risk of injury in a crash.

Remedy: DTNA will notify owners, and dealers will inspect the seats, installing any missing reinforcement brackets, free of charge. An interim notice was mailed to owners on November 7, 2017. The recall began on March 15, 2018. Owners may contact DTNA customer service at 1-800-547-0712. DTNA's number for this recall is FL-747.

NHTSA campaign record ↗
17V589000 · Seats

Reported: 2017-09-21 (September 21, 2017)

Daimler Trucks North America LLC (DTNA) is recalling certain 2014-2018 Thomas Built Buses Saf-T-Liner HDX and Saf-T-Liner C2 transit buses. A reinforcement bracket may be missing from the seats that have 3-point seat belts.

Consequence: Without the reinforcement bracket, the seat may not remain adequately secured, increasing the risk of injury in a crash.

Remedy: DTNA will notify owners, and dealers will inspect the seats, installing any missing reinforcement brackets, as needed, free of charge. An interim notice was sent to owners on November 7, 2017. The recall began on March 14, 2018. Owners may contact DTNA customer service at 1-800-547-0712. DTNA's number for this recall is FL-747.

NHTSA campaign record ↗
17V665000 · Fuel System, Other:Delivery:Hoses, Lines/Piping, And Fittings

Reported: 2017-10-19 (October 19, 2017)

Daimler Trucks North America LLC (DTNA) is recalling certain 2012-2018 Thomas Built Bus Saf-T-Liner C2 school buses. The affected vehicles are propane-powered and have propane fuel lines that may contact the transmission yoke, possibly causing a propane leak.

Consequence: A propane leak in the presence of an ignition source can increase the risk of a fire.

Remedy: DTNA will notify owners, and dealers will inspect the propane line routing, correcting it as necessary, free of charge. DTNA issued owners an interim notification on December 14, 2017. Owners may contact DTNA customer service at 1-800-547-0712. DTNA's number for this recall is FL-752.

NHTSA campaign record ↗
18V190000 · Fuel System, Other:Delivery:Hoses, Lines/Piping, And Fittings

Reported: 2018-03-26 (March 26, 2018)

Daimler Trucks North America LLC (DTNA) is recalling certain 2014-2019 Thomas Built Buses Saf-T-Liner C2 school buses equipped with propane engines. The propane fuel line may contact the j-hook body support bracket that could cause chafing resulting in a propane leak.

Consequence: A propane leak in the presence of an ignition source can increase the risk of a fire.

Remedy: DTNA will notify owners, and dealers will inspect the propane line clearance and reroute the line if needed. Any damaged lines will be replaced. These repairs will be performed free of charge. DTNA issued an interim notification to owners on May 9, 2018. The recall began on July 3, 2018. Owners may contact DTNA customer service at 1-800-547-0712. DTNA's number for this recall is FL-765.

NHTSA campaign record ↗
18V192000 · Seats

Reported: 2018-03-26 (March 26, 2018)

Daimler Trucks North America LLC (DTNA) is recalling certain 2014-2018 Thomas Built Buses Saf-T-Liner C2, Saf-T-Liner HDX, Saf-T-Liner EFX, and Minotour school buses, equipped with certain Syntec-brand S3B, Non-Restraint, Wall Mounted Seats. The wall mounting bracket may crack, which may cause the seat to not remain secured in place in the event of a crash.

Consequence: In the event of a crash, if the seat does not remain secured to the wall, the occupant has an increased risk of an injury.

Remedy: DTNA will notify owners, and dealers will install an additional wall mounting bracket, free of charge. DTNA issued an interim notification to owners on May 9, 2018. The recall began May 10, 2018. Owners may contact DTNA customer service at 1-800-547-0712. DTNA's number for this recall is FL-763.

NHTSA campaign record ↗
18V193000 · Seats

Reported: 2018-03-26 (March 26, 2018)

Daimler Trucks North America LLC (DTNA) is recalling certain 2014-2018 Thomas Built Buses Saf-T-Liner C2, Saf-T-Liner HDX, Saf-T-Liner EFX, and Minotour transit buses, equipped with certain Syntec-brand S3B, Non-Restraint, Wall Mounted Seats. The wall mounting bracket may crack, which may cause the seat to not remain secured in place in the event of a crash.

Consequence: In the event of a crash, if the seat does not remain secured to the wall, the occupant has an increased risk of an injury.

Remedy: DTNA will notify owners, and dealers will install an additional wall mounting bracket, free of charge. DTNA issued an interim notification to owners on May 10, 2018. The recall began May 10, 2018. Owners may contact DTNA customer service at 1-800-547-0712. DTNA's number for this recall is FL-763.

NHTSA campaign record ↗
18V250000 · Electrical System:12v/24v/48v Battery:Cables

Reported: 2018-04-19 (April 19, 2018)

Daimler Trucks North America LLC (DTNA) is recalling certain 2018-2019 Thomas Built Buses Saf-T-Liner C2 transit buses equipped with 2 8D batteries. The battery power cable may have inadequate clearance between the cable and the battery hold down bracket when the battery tray is pulled out for service, causing the cable to rub against the bracket.

Consequence: The battery cable rubbing may cause the cable to short circuit, increasing the risk of a fire.

Remedy: DTNA will notify owners, and dealers will be inspect the battery cables and reroute them for proper clearance, as required, free of charge. Daimler issued an interim notification to owners on June 18, 2018. The recall began October 3, 2018. Owners may contact DTNA customer service at 1-800-547-0712. DTNA's number for this recall is FL768.

NHTSA campaign record ↗
18V253000 · Seats

Reported: 2018-04-19 (April 19, 2018)

Daimler Trucks North America LLC (DTNA) is recalling certain 2014-2018 Thomas Built Buses Saf-T-Liner C2, Saf-T-Liner HDX, Saf-T-Liner EFX, and Minotour school buses equipped with S3B Restraint Wall Mounted Seats. The wall mounting bracket may crack, causing the seat to not remain secured in place in the event of a crash.

Consequence: In the event of a crash, if the seat does not remain secured to the wall, the occupant has an increased risk of an injury.

Remedy: DTNA will notify owners, and dealers will install an additional wall mounting bracket, free of charge. Daimler issued owners an interim notification on June 12, 2018. The recall began January 3, 2019. Owners may contact DTNA customer service at 1-800-547-0712. DTNA's number for this recall is FL-769.

NHTSA campaign record ↗
18V254000 · Seats

Reported: 2018-04-19 (April 19, 2018)

Daimler Trucks North America LLC (DTNA) is recalling certain 2014-2018 Thomas Built Buses Saf-T-Liner C2, Saf-T-Liner EFX, Saf-T-Liner HDX, and Minotour transit buses, equipped with certain S3B Restraint Wall Mounted Seats. The wall mounting bracket may crack, causing the seat to not remain secured in place in the event of a crash.

Consequence: In the event of a crash, if the seat does not remain secured to the wall, the occupant has an increased risk of an injury.

Remedy: DTNA will notify owners, and dealers will install an additional wall mounting bracket, free of charge. Daimler issued an interim notification to owners on June 15, 20 18. The recall began January 3, 2019. Owners may contact DTNA customer service at 1-800-547-0712. DTNA's number for this recall is FL-769.

NHTSA campaign record ↗
18V352000 · Service Brakes, Hydraulic:Foundation Components:Disc:Caliper

Reported: 2018-05-29 (May 29, 2018)

Daimler Trucks North America LLC (DTNA) is recalling certain 2017-2019 Thomas Built Buses Saf-T-Liner C2, Saf-T-Liner EFX and Saf-T-Liner HDX school buses equipped with air disc brakes. The brake caliper mounting bolts on these vehicles may be insufficiently tightened, allowing the bolts to loosen.

Consequence: If the brake caliper mounting bolts come loose, braking performance may be reduced, increasing the risk of a crash.

Remedy: DTNA will notify owners, and dealers will inspect the brake caliper mounting bolts and tighten them as necessary, free of charge. DTNA issued owners an interim notification on July 25, 2018. The recall began September 4, 2018. Owners may contact DTNA customer service at 1-800-547-0712. DTNA's number for this recall is FL-772.

NHTSA campaign record ↗
18V378000 · Electrical System:12v/24v/48v Battery:Cables

Reported: 2011-06-07 (June 7, 2011)

Daimler Trucks North America, LLC (DTNA) is recalling certain 2018 Thomas Built Buses Saf-T-Liner C2 transit buses equipped with two 8D batteries. The battery power cable may not have adequate clearance between the cable and battery hold down bracket. As a result, the cable can rub against the bracket damaging the cable.

Consequence: The damaged battery cable may electrically arc, increasing the risk of a fire.

Remedy: DTNA will notify owners, and dealers will inspect the battery cable routing, rerouting it as necessary to provide the proper clearance, free of charge. DTNA issued owners an interim notification on August 6, 2018. The recall began October 3, 2018. Owners may contact DTNA customer service at 1-800-547-0712. DTNA's number for this recall is FL-768.

NHTSA campaign record ↗
18V560000 · Equipment Adaptive/Mobility

Reported: 2018-08-23 (August 23, 2018)

Daimler Trucks North America LLC (DTNA) is recalling certain 2015-2019 Thomas Built Buses Saf-T-Liner C2 and Saf-T-Liner HDX school buses, equipped with certain S-Series and K-Series Titanium Wheelchair Lifts, models K200, K201, K550, K551, S200, S2201, S550 and S551. The wheelchair lift positioning input cam may fail while the lift is in use, allowing the platform to travel higher than the vehicle's floor height.

Consequence: If the wheelchair lift platform stops above the vehicle floor, the wheelchair user can tip inwards toward the vehicle when exiting the lift, increasing their risk of injury.

Remedy: Dealers will replace the injection molded cam with an aluminum machined cam, free of charge. The recall began December 6, 2018. Owners may contact DTNA customer service at 1-800-547-0712. DTNA's number for this recall is FL785.

NHTSA campaign record ↗
18V561000 · Seats

Reported: 2018-08-23 (August 23, 2018)

Daimler Trucks North America LLC (DTNA) is recalling certain 2017-2019 Thomas Built Buses Saf-T-Liner C2 school buses, equipped with S3B 45" Restraint School Bus Seats. In the event of a crash, the seat's foot may pull through the bolted joint at the bus floor. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard (FMVSS) number 210, "Seat Belt Assembly Anchorages."

Consequence: In the event of a crash, if the seat detaches from the floor, it can increase the risk of injury.

Remedy: DTNA will notify owners, and dealers will install a washer between the rear mounting foot, and the bus floor to keep the seat secured, free of charge. The recall began October 17, 2018. Owners may contact DTNA customer service at 1-800-547-0712. DTNA's number for this recall is FL787.

NHTSA campaign record ↗
18V702000 · Service Brakes, Air:Disc:Caliper

Reported: 2018-10-05 (October 5, 2018)

Daimler Trucks North America, LLC (DTNA) is recalling certain 2018-2019 Thomas Built school buses Saf-T-Liner C2, Saf-T-Liner HDX and Saf-T-Liner EFX school buses. The brake caliper mounting bolts may have been insufficiently tightened.

Consequence: Loose brake caliper mounting bolts can reduce brake effectiveness, increasing the risk of a crash.

Remedy: DTNA has notified owners, and dealers will check and tighten the brake caliper mounting bolts, free of charge. The recall began December 3, 2018. Owners may contact DTNA customer service at 1-800-547-0712. DTNA's number for this recall is FL-794.

NHTSA campaign record ↗
18V877000 · Structure:Body:Roof And Pillars

Reported: 2018-12-10 (December 10, 2018)

Daimler Trucks North America LLC (DTNA) is recalling certain 2017-2019 Thomas Built Buses Saf-T-Liner C2 school buses. The roof adhesive that supports the roof header may not have been properly applied.

Consequence: Improperly applied adhesive may affect the roof header joint strength, which, in the event of a rollover crash, can increase the risk of injury.

Remedy: DTNA will notify owners, and dealers will inspect the placement of the roof header adhesive, and install mechanical fasteners, as necessary, free of charge. DTNA issued owners an interim notification on February 1, 2019. The recall began March 25, 2020. Owners may contact DTNA customer service at 1-800-547-0712. DTNA's number for this recall is FL-801.

NHTSA campaign record ↗
18V878000 · Structure:Body:Roof And Pillars

Reported: 2018-12-10 (December 10, 2018)

Daimler Trucks North America LLC (DTNA) is recalling certain 2017-2019 Thomas Built Buses Saf-T-Liner C2 transit buses. The roof adhesive that supports the roof header may not have been properly applied.

Consequence: Improperly applied adhesive may affect the roof header joint strength, which, in the event of a rollover crash, can increase the risk of injury.

Remedy: DTNA will notify owners, and dealers will inspect the placement of the roof header adhesive, and install mechanical fasteners, as necessary, free of charge. DTNA issued and interim notification to owners on February 1, 2019. The recall began March 25, 2020. Owners may contact DTNA customer service at 1-800-547-0712. DTNA's number for this recall is FL-801.

NHTSA campaign record ↗
18V914000 · Suspension:Front:Control Arm | Steering:Linkages:Tie Rod Assembly | Steering

Reported: 2018-12-19 (December 19, 2018)

Daimler Trucks North America LLC (DTNA) is recalling certain 2018-2019 Thomas Built Saf-T-Liner HDX, C2, and EFX School Buses, equipped with Detroit Axle axles. The affected vehicles may have loose steering tie rod arm bolts.

Consequence: Loose tie rod arm bolts may lead to separation of the tie rod arm, affecting vehicle steering, and increasing the risk of a crash.

Remedy: DTNA has notified owners, and dealers will inspect the steering arm and tie rod arm bolts for to make sure that they are properly tightened, installing new fasteners as necessary, free of charge. The recall began February 9, 2019. Owners may contact Daimler Trucks at 1-800-547-0712. DTNA's number for this recall is FL-802.

NHTSA campaign record ↗
19V444000 · Service Brakes, Air:Disc

Reported: 2019-06-11 (June 11, 2019)

Daimler Trucks North America LLC (DTNA) is recalling certain 2010-2020 Thomas Built Buses Saf-T-Liner C2, 2016-2019 HDX, and 2017-2019 EFX school buses equipped with Bendix Air Disc Brakes. The driver side rear brakes may drag.

Consequence: The dragging brakes may lead to high temperatures at the wheel end, increasing the risk of smoke and fire, possibly resulting in the bus having to be evacuated, which can increase the risk of injury.

Remedy: DTNA will notify owners, and dealers will install a new caliper with an updated clearance adjustment mechanism, free of charge. The recall began August 9, 2019. Owners may contact DTNA customer service at 1-800-547-0712. DTNA's number for this recall is FL-818.

NHTSA campaign record ↗
19V686000 · Power Train:Automatic Transmission:Torque Converter

Reported: 2019-09-27 (September 27, 2019)

Daimler Trucks North America LLC (DTNA) is recalling certain 2017-2020 Saf-T-Liner C2 school buses equipped with Detroit DD5 engines and Allison transmissions. The Flex-Plate/Torque Converter fasteners may have been insufficiently tightened.

Consequence: The loose bolts may lead a disabled school bus and result in a school bus evacuation procedure in an uncontrolled traffic situation, increasing the risk of an injury.

Remedy: DTNA will notify owners, and dealers will inspect and tighten the fasteners, as necessary, free of charge. The recall began November 19, 2019. Owners may contact DTNA customer service at 1-800-547-0712. DTNA's number for this recall is FL-828.

NHTSA campaign record ↗
19V712000 · Seats

Reported: 2019-10-04 (October 4, 2019)

Daimler Trucks North America LLC (DTNA) is recalling certain 2014-2020 Thomas Built Saf-T-Liner EFX, Minotour, Saf-T-Liner C2, and Saf-T-Liner HDX school buses equipped with SynTec S3B or S3C seats. The seats may have been manufactured with styrene blocks that may not provide sufficient impact absorption in certain specific areas around the steel seat frame of the back support. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard (FMVSS) number 222, "School Bus Passenger Seating and Crash Protection."

Consequence: The lack of impact absorption increases the risk of injury in the event of a crash.

Remedy: DTNA will notify owners, and dealers will install additional impact material between the re-bond back and the vinyl back cover to increase the amount of absorption, free of charge. DTNA issued owners an interim notification on November 29, 2019. The recall began June 22, 2020. Owners may contact DTNA customer service at 1-800-547-0712. DTNA's number for this recall is FL-832.

NHTSA campaign record ↗