vehicle signal
U.S. public vehicle records

2014 Ic Bus HC: complaints, problems and recalls

Explore the records behind recurring owner reports.

Key facts

0 owner complaints analyzed

2 distinct recall campaigns

Not available median reported failure mileage

Scope: 2014 model year. Data snapshot: . 0 complaints include usable failure mileage.

Owner-reported patterns

Most common problems

No owner complaints are recorded for this selection. A complaint can name multiple components.

Component breakdown

Number of unique complaints naming each component. Top eight shown.

No usable records for this chart.

Component breakdown data
CategoryCount

No records.

Reported problems by failure mileage

Complaint counts in mileage bands. These are not failure rates per vehicle or mile.

Under 25,000
0
25,000 to 49,999
0
50,000 to 74,999
0
75,000 to 99,999
0
100,000 to 149,999
0
150,000 and above
0
Reported problems by failure mileage data
CategoryCount
Under 25,0000
25,000 to 49,9990
50,000 to 74,9990
75,000 to 99,9990
100,000 to 149,9990
150,000 and above0

Under 25,000: 0; 25,000 to 49,999: 0; 50,000 to 74,999: 0; 75,000 to 99,999: 0; 100,000 to 149,999: 0; 150,000 and above: 0

No usable failure mileage is recorded. 0 complaints have missing, zero or invalid mileage.

Complaints over time

Year the complaint was filed, not the vehicle model year or incident year. The snapshot year is partial.

No usable records for this chart.

Complaints over time data
CategoryCount

No records.

Pattern summary

There is not enough complaint evidence to summarize patterns.

Calculated from recorded counts. An AI narrative has not been published for this selection.

Examples from the source records

Examples provide context, not a representative sample or a verified diagnosis.

Recall history

2 distinct campaigns affect this selection. Announcement dates below are different from vehicle model years. A campaign may cover multiple years.

15V241000 · Visibility:Defroster/Defogger/Hvac System:Fan/Motor

Reported: 2015-04-22 (April 22, 2015)

Navistar, Inc. (Navistar) is recalling certain model year 2011-2015 International DuraStar, ProStar, TranStar and WorkStar, 2012-2015 International TerraStar, 2013-2015 International LoneStar and IC Bus HC, and 2014-2015 IC Bus AC vehicles. A vehicle double battery jump start or electrical load dump event could result in an overvoltage condition of a component within the HVAC system linear power module (LPM) which is used to control the blower speed. The overvoltage condition could result in the overheating and failure of the LPM.

Consequence: If the LPM overheats and fails, there is an increased risk of a fire.

Remedy: Navistar will notify owners, and dealers will replace the LPM with an upgraded one, free of charge. An interim letter was mailed to owners on June 18, 2015. A second notification will mailed when parts become available. The recall began on August 6, 2015. Owners may contact Navistar customer service at 1-800-448-7825. Navistar's number for this recall is 15509.

NHTSA campaign record ↗
15V394000 · Electrical System:Wiring

Reported: 2015-06-22 (June 22, 2015)

Navistar, Inc. (Navistar) is recalling certain model year 2010-2014 International Durastar trucks manufactured May 13, 2009, to June 24, 2013, 2011-2012 International Workstar trucks manufactured November 30, 2010, to September 26, 2011, and 2010-2014 IC Bus HC transit buses manufactured November 19, 2009, to April 24, 2013. The affected vehicles may have an improperly routed engine grid heater power feed cable which can result in the cable contacting the metal edge on the cab.

Consequence: If the cable contacts the metal edge of the cab, it may cause an electrical short, increasing the risk of a fire.

Remedy: Navistar will notify owners, and dealers will secure the power feed cable so that it cannot contact the cab, free of charge. The recall began on August 3, 2015. Owners may contact Navistar customer service at 1-800-448-7825. Navistar's number for this recall is 15514.

NHTSA campaign record ↗