vehicle signal
U.S. public vehicle records

Horton Ambulance 603 recalls by model year

Explore the records behind recurring owner reports.

Key facts

0 owner complaints analyzed

4 distinct recall campaigns

Not available median reported failure mileage

Scope: 2013 to 2017 model years. Data snapshot: . 0 complaints include usable failure mileage.

Compare model years

Recalls by model year

All campaigns in the snapshot affecting each model year, including recalls announced years later.

Recall campaigns

Shared campaigns appear once in each affected model year.

2013
1
2014
2
2015
2
2016
1
2017
1
Recall campaigns data
CategoryCount
20131
20142
20152
20161
20171

2013: 1; 2014: 2; 2015: 2; 2016: 1; 2017: 1

Year-by-year records

Horton Ambulance 603 model-year comparison
Model yearComplaintsRecallsChange in recalls
201301Not available
201402+1
2015020
201601-1
2017010

Recall history

4 distinct campaigns affect this selection. Announcement dates below are different from vehicle model years. A campaign may cover multiple years.

16V625000 · Equipment:Appliance:Air Conditioner

Reported: 2016-08-26 (August 26, 2016) · Model years: 2013, 2014, 2015, 2016

Halcore Group, Inc. (Halcore) is recalling certain model year 2013-2016 Horton ambulances, models 453, 457, 503, 553, 603, and 623, manufactured November 29, 2013, to March 1, 2016. The affected vehicles may have an improperly sealed Cool-Tech air-conditioning condenser controller wire harness that can allow water to enter the controller housing.

Consequence: If water gets into the controller housing, the controller may short circuit, increasing the risk of an electrical fire.

Remedy: Halcore will notify owners, and dealers will replace the Cool-Tech condenser fan controller assembly, free of charge. Halcore issued an interim notification to owners on September 9, 2016. The recall began on October 26, 2016. Owners may contact Horton customer service at 1-614-317-9856, or by email at warranty@hortonambulance.com

NHTSA campaign record ↗
14V558000 · Suspension

Reported: 2014-09-12 (September 12, 2014) · Model years: 2014

Halcore Group, Inc. (Halcore) is recalling certain model year 2014 Horton ambulances, models 403, 453, 457, 603, and 623 manufactured February 1, 2014, and August 31, 2014, and equipped with Liquid Spring-brand aftermarket suspension kits. The mounting bracket that attaches the suspension fluid tank to the frame may fail, allowing the fluid tank to separate from the vehicle.

Consequence: If the suspension fluid tank mount fractures and the tank separates from the chassis, the tank may become a road hazard, increasing the risk of a crash.

Remedy: Halcore will notify owners, and Halcore dealers will install a re-designed bracket, free of charge. The recall began in October 2014. Owners may contact Halcore customer service at 1-614-539-8181. Owners may also contact Liquid Spring customer service at 1-765-474-7816 extension 109.

NHTSA campaign record ↗
15V828000 · Electrical System

Reported: 2015-12-09 (December 9, 2015) · Model years: 2015

Halcore Group, Inc. (Halcore) is recalling certain model year 2015 Horton 623, 603, 503, 553 and 453 ambulances manufactured October 1, 2015, to November 16, 2015 and equipped with the i4G system for controlling the ambulance body electrics. Due to a circuit board component being installed incorrectly, the ambulance body may have electrical system failure of the interior and exterior lights, as well as other life saving electrical equipment such as the oxygen system.

Consequence: Failure of ambulance body electrics can hinder emergency response and/or rescue efforts, increasing the risk of injury to ambulance patients.

Remedy: Halcore will notify owners, and Horton will replace the affected electrical component, free of charge. The recall began on January 4, 2016. Owners may contact Horton customer service at 1-800-282-5113.

NHTSA campaign record ↗
17V122000 · Service Brakes, Hydraulic:Foundation Components:Hoses, Lines/Piping, And Fittings

Reported: 2017-02-27 (February 27, 2017) · Model years: 2017

Halcore Group, Inc. (Halcore) is recalling certain 2017 Horton ambulances, models 623, 603F, 453, and 457, built on Ford F-350, F-450, or F-550 chassis equipped with Compressible Liquid Adaptive Suspension Systems (C.L.A.S.S.) made by LiquidSpring. Due to an incorrect torque specification, the rear brake caliper banjo bolts may have been overtightened.

Consequence: The improperly tightened banjo bolts may result in a partial or complete loss of rear brake power, increasing the risk of a crash.

Remedy: Horton will notify owners, and LiquidSpring dealers will replace the rear brake banjo bolts, free of charge. The recall began on March 7, 2017. Owners may contact LiquidSpring customer service at 1-765-474-7816, extension 1, or at service@liquidspring.com or Horton customer service at 1-614-534-8181.

NHTSA campaign record ↗