Demers Ambulances TYPE I (MXP150E) recalls by model year
Explore the records behind recurring owner reports.
Key facts
0 owner complaints analyzed
1 distinct recall campaigns
Not available median reported failure mileage
Scope: 2019 to 2020 model years. Data snapshot: . 0 complaints include usable failure mileage.
This selection has limited data. It remains available for lookup but is excluded from search indexing.
Recalls by model year
All campaigns in the snapshot affecting each model year, including recalls announced years later.
Recall campaigns
Shared campaigns appear once in each affected model year.
| Category | Count |
|---|---|
| 2019 | 1 |
| 2020 | 1 |
2019: 1; 2020: 1
Year-by-year records
Recall history
1 distinct campaigns affect this selection. Announcement dates below are different from vehicle model years. A campaign may cover multiple years.
20V323000 · Service Brakes | Service Brakes, Hydraulic:Foundation Components:Hoses, Lines/Piping, And Fittings | Suspension:Rear
Reported: 2020-06-04 (June 4, 2020) · Model years: 2019, 2020
Braun Ambulances (Braun) is recalling certain 2019-2020 Demers MXP170E Type I and MXP150E Type I ambulances built on Ram 4500 and 5500 chassis equipped with Compressible Liquid Adaptive Suspension Systems (C.L.A.S.S.), part numbers DS135RS3A, DS135RS3AF and DS135RS3-DM. The rear brake caliper flexible line may have been routed so that it contacts a suspension component, possibly causing excessive wear and a loss of rear brakes.
Consequence: A worn rear brake caliper flexible line may cause brake fluid leakage which may result in a partial or complete loss of the rear brakes, increasing the risk of a crash.
Remedy: Braun will notify owners and dealers will replace the rear brake caliper flexible lines and hardware, free of charge. The recall began July 21, 2020. Owners may contact Demers customer service at 1-800-363-7591.