Altec CRANE recalls by model year
Explore the records behind recurring owner reports.
Key facts
0 owner complaints analyzed
5 distinct recall campaigns
Not available median reported failure mileage
Scope: 2008 to 2024 model years. Data snapshot: . 0 complaints include usable failure mileage.
Recalls by model year
All campaigns in the snapshot affecting each model year, including recalls announced years later.
Recall campaigns
Shared campaigns appear once in each affected model year.
| Category | Count |
|---|---|
| 2008 | 1 |
| 2009 | 1 |
| 2010 | 1 |
| 2011 | 1 |
| 2012 | 1 |
| 2013 | 1 |
| 2014 | 2 |
| 2015 | 3 |
| 2016 | 3 |
| 2017 | 3 |
| 2018 | 4 |
| 2019 | 1 |
| 2022 | 1 |
| 2023 | 1 |
| 2024 | 1 |
2008: 1; 2009: 1; 2010: 1; 2011: 1; 2012: 1; 2013: 1; 2014: 2; 2015: 3; 2016: 3; 2017: 3; 2018: 4; 2019: 1; 2022: 1; 2023: 1; 2024: 1
Year-by-year records
Recall history
5 distinct campaigns affect this selection. Announcement dates below are different from vehicle model years. A campaign may cover multiple years.
18V791000 · Electrical System:12v/24v/48v Battery:Cables | Electrical System:Wiring:Fuses And Circuit Breakers
Reported: 2018-11-09 (November 9, 2018) · Model years: 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017, 2018
Altec Industries, Inc. (Altec) is recalling certain 2008-2018 Altec AC18, AC23, AC26, AC30 and AC38 Cranes and D2B, D3A, D4A/B, DL42B, DT65 and DT80 Digger Derrick vehicles. The wiring on the 12V circuit from the chassis battery to the Power Distribution Module (PDM) may be insufficiently sized.
Consequence: The insufficiently sized wire may overheat, increasing the risk of fire.
Remedy: Altec will notify owners, and dealers will replace the wiring to the PDM, with a larger wire and/or replace the circuit breaker, free of charge. The recall began January 9, 2019. Owners may contact Altec customer service at 1-877-462-5832. Altec's number for this recall is CSN 703.
NHTSA campaign record ↗18V708000 · Electrical System:Software | Electrical System: Instrument Cluster/Panel
Reported: 2018-10-09 (October 9, 2018) · Model years: 2014, 2015, 2016, 2017, 2018
Altec Industries Inc. (Altec) is recalling certain 2014-2018 Altec AC40-152S Cranes. On the affected cranes, the electronic Load Moment and Area Protection (LMAP) screen may display incorrect load chart values.
Consequence: Using an incorrect chart value could lead to unit instability or loss of load control, increasing the risk of injury.
Remedy: Altec will notify owners, and dealers will update the LMAP software, as necessary, free of charge. The recall is expected to begin on December 4, 2018. Owners may contact Altec at 1-205-991-7733. Altec's number for this recall is CSN 696.
NHTSA campaign record ↗20V034000 · Equipment
Reported: 2020-01-22 (January 22, 2020) · Model years: 2015, 2016, 2017, 2018, 2019
Altec Industries Inc. (Altec) is recalling certain 2015-2019 Altec AC26, AC28, AC30, and AC38 Crane Aerial Devices. The boom lift cylinder hose may have been connected to a port that does not have an internal velocity fuse. Failure of a boom lift cylinder hose that is not protected by a velocity fuse can result in uncontrolled boom movement.
Consequence: Uncontrolled movement of the boom lift increases the risk of injury.
Remedy: Altec will notify owners and will inspect the hose to verify that it is connected properly, repairing it as necessary, free of charge. The recall began January 30, 2020. Owners may contact Altec customer service at 1-877-462-5832. Altec's number for this recall is MAB 748.
NHTSA campaign record ↗18V617000 · Structure
Reported: 2018-09-12 (September 12, 2018) · Model years: 2018
Altec Industries Inc. (Altec) is recalling certain 2018 Altec AC18, AC23, AC30, AC40, AC45 Cranes, D2045, DT65 Digger Derricks, and AA55 Aerial Devices. The rotation platform fasteners may have been overtightened, possibly resulting in the fasteners breaking.
Consequence: If the fasteners break, the pedestal or turntable may separate from the vehicle, increasing the risk of injury.
Remedy: Altec has notified owners, and the rotation bearing fasteners will be replaced, free of charge. The recall began on September 21, 2018. Owners may contact Altec customer service at 1-877-462-5832. Altec's number for this recall is MAB 692.
NHTSA campaign record ↗24V821000 · Equipment:Mechanical:Integrated Jack/Leveler/Stabilizer
Reported: 2024-10-31 (October 31, 2024) · Model years: 2022, 2023, 2024
Altec Industries, Inc. (Altec) is recalling certain 2022-2024 AC series cranes. The crane outrigger shoes may have been improperly manufactured, which can cause them to crack and fail under load, reducing the cranes stability.
Consequence: A loss of stability during operation could cause the crane to fall, increasing the risk of an injury.
Remedy: Altec will replace the outrigger shoes, free of charge. Owner notification letters were mailed December 20, 2024. Owners may contact Altec customer service at 1-877-462-5832. Altec's number for this recall is CSN-3194.
NHTSA campaign record ↗